Specifications
Input data
Input
0 ... 20 mA (linear transmission up to 22 mA)
Operating current
<100 µA
Voltage drop
Approx. 2.7 V at 20 mA
Overload
50 mA, 15 V
Output data
Output
0 ... 20 mA, ≤500 ohms
Residual ripple
<10 mVrms
Transmission behavior
Transmission error
<0.1 % full scale
Load error
<0.05 % meas.val. / 100 ohms
Response time (T99)
Approx. 5 ms at 500 ohms load
Temperature coefficient 1)
<0.005 %/K full scale per 100 ohms load (reference temperature 23 °C)
Isolation
Test voltage
510 V AC
Working voltage
100 V with overvoltage category II and pollution degree 2 according to EN 61010-1
Standards and approvals
EMC2)
89/336/EEC directive, EN 61326
Other data
Ambient temperature
Operation:
–25 ... +60 °C also when mounted in a row
Transport and storage:
–40 ... +85 °C
Housing
Terminal housing, 6 mm width, connection using Z-spring technology See dimension drawings for further measurements
Protection class
IP 20 in row or with end plate
Mounting
For 35 mm top hat rail EN 50022 see dimension drawings for conductor cross section
Weight
12 g
1) Average TC in specific working temperature range –25 ºC ... +60 °C
2) Applies to 4 ... 20 mA, slight deviations are possible while there is interference