国产精品久久久久久亚洲,国产成人无码午夜视频在线观看 ,国产福利一区二区三区在线观看,国产av第一次处破,厨房玩弄丝袜人妻系列国产电影

首頁(yè) >>> 產(chǎn)品目錄 >>> Data Logger
儀表展覽網(wǎng) >>> 展館展區(qū) >>> 其他工控設(shè)備 >>> DCS系統(tǒng) >>> Yokogawa Small Electric Power Input Module AAM21J
> Yokogawa Small Electric Power Input Module AAM21J

產(chǎn)品資料

Yokogawa Small Electric Power Input Module AAM21J[產(chǎn)品打印頁(yè)面]

Yokogawa Small Electric Power Input Module AAM21J
  • 如果您對(duì)該產(chǎn)品感興趣的話,可以
  • 產(chǎn)品名稱:Yokogawa Small Electric Power Input Module AAM21J
  • 產(chǎn)品型號(hào):AAM21J
  • 產(chǎn)品展商:Yokogawa
  • 產(chǎn)品文檔:無(wú)相關(guān)文檔
簡(jiǎn)單介紹
Yokogawa Small Electric Power Input Module AAM21J, Yokogawa Small Electric Power Input Module AAM21J, CENTUM CS 3000 and CENTUM CS 1000 systems. Please contact us: tekrachel @ 163.com
產(chǎn)品描述

Yokogawa Small Electric Power Input Module AAM21J 

mV, Thermocouple, and RTD Input Module (supports IEC584-1995, IEC751-1995)

GENERAL

I/O Modules and I/O Module Nests (for RIO) for CENTUM CS 3000 and CENTUM CS 1000 systems.


STANDARD SPECIFICATIONS

I/O Module Nest

Yokogawa Small Electric Power Input Module AAM21J

Power Supply: 5.0 V DC supplied from Model AND50, ANS50, AND20, ANS20 Node Interface Unit or Model PFCS/ PFCD Field Control Station

Installation:   Node Interface Unit, I/O Expansion Rack, or  Model PFCS/PFCD Field Control Station.

External Dimensions: 125mm (W) x 130mm (D) x 248mm (H); 

                       AMN51:  137.5mm (W) x 225mm (D) x 254 (H); 

                      AMN52: 233.3mm (W) x 225mm (D) x 254mm (H)

Weight:  Max. 2.5 kg (AMN52. This weight does not include I/O Modules.)

Models

Names

CS 1000

CS 3000

 

Installation Restrictions

(See next page)

AFS10S,AFS10D

 

AFG10S,AFG10D AFG20S,AFG20D

PFCS PFCD

AMN11

Nest for Analog I/O Modules

X

X

X

 

AMN12

High-Speed Nest for Analog I/O Modules

 

X

 

(*1)

AMN21

Nest for Relay I/O Modules

X

X

X

 

AMN31

Nest for Terminal I/O Modules

X

X

X

(*2)

AMN32

Nest for Connector I/O Modules

X

X

X

 

AMN33

Nest for Communication Modules

X

X

X

 

AMN34

Nest for Multipoint Control Analog I/O Modules

X

X

X

 

AMN51

Nest for Communication Cards

X

 

X

(*3)

AMN52

Nest for PROFIBUS Communication Module

X (*5)

 

X (*5)

(*4)


Small Electric Power Input Module

This module receives signals from mV, thermocouple, RTD and potentiometer.

Yokogawa Small Electric Power Input Module AAM21J

Item

Specifications

Model

AAM21J, AAM21JJ (*4)

 

Input signal

 

mV

JIS,IEC Standard Thermocouple type K, T, J, E, B (*1), R, S, IEC Standard type N

 

RTD JIS JPt100 or

JIS Pt100 (DIN Pt100)

3-wire type

 

3-wire potentiometers

 

 

Input range

 

 

-50 to 150 mV

 

 

-50 to 150 mV

 

 

0 to 333 ?

The total residence is within 100 to 2000 ?, and the span is 50 % or more of the total resistance.

(*2)

Allowable input voltage

-0.5 to 4.0 V DC (between terminals B-C)

-

Input resistance

1 M V at power-up (3 k V at power-down)

-

Accuracy

±20 μV

±20 μV

±0.08 V

±0.2 %

Data update period

100 ms

Signal source resistance

1000 ? or less

150 ? or less (wiring resistance per wire)

RJC input

-

-10 to 70 °C

-

RJC accuracy

-

Within ± 1 °C (*3)

-

Measuring current

-

1 mA

-

 

 

Auxiliary voltage output

1 to 5 V DC (Signal ground is shared with system) Output resistance: 1 ? or less

Allowable load resistance: 10 k? or more

Output range: 0.5 to 5.5 V DC Accuracy: ±12 mV

Burnout detection

Select from UP/DOWN/OFF (*5)

Burnout detection time

Within 60 sec

Burnout detection current

0.1 μA (terminal B only) (*5)

How installed

Installed in AMN11 Nest for Analog I/O Modules

How connected

Connected to the terminals of the I/O module nest with M4 screws

Signal isolation

Input signals are isolated between systems. Withstanding voltage: 1500 V AC/min

Current consumption

150 mA or less (5.0 V DC)

Input linearization

None

Available

Available

None

 

Effect of signal source resistance/wiring resistance (burnout is OFF)

 

 

1 k? of signal source resistance: Input conversion

± 20 μV or less

Wiring resistance 10 ? for terminals A and C: In- put conversion ±40 m? or less (Wiring of terminals

A and C must have the same resistance)

 

 

-

 

Effect of ambient temperature change

For 10 °C change:   mV input:                       ±40 μ

                                      Thermocouple input:     ±40 μ

                                      RTD input:                        ±0.16 ?

                                     Potentiometer input:       ±0.4 % of span

                                    Auxiliary voltage output: ±24 mV

 

 

-

How input signals are specified

 Specify input signals and range by software setting.

Option Specifications for Thermocouple

When using the AAM21J for thermocouple input, order the temperature compensation module for each channel.

 

 

Description

Model

AAM21J, AAM21JJ

 

Option Code

/RJ

Temperature Compensation Module for Thermocouple Input