醫(yī)院環(huán)境物體表面清潔的監(jiān)測(cè)熒光套裝LUYOR-3130C熒光標(biāo)記法
LUYOR-3130C熒光監(jiān)測(cè)套裝包含LUYOR-3130強(qiáng)光紫外線手電筒一只,LUV-10紫外線防護(hù)眼鏡一副,五只熒光記號(hào)筆,充電電池二節(jié)、充電器一只,手提箱一只。
警告:
目前,路陽(yáng)所有的熒光標(biāo)記套裝均不屬于醫(yī)療器械產(chǎn)品,均未根據(jù)任何適用法律認(rèn)證和批準(zhǔn)用作醫(yī)療器械或用于醫(yī)療器械的表面檢查。路陽(yáng)未計(jì)劃在世界任何地方將其用作醫(yī)療器械,所有路陽(yáng)的熒光標(biāo)記套裝切勿用于醫(yī)療機(jī)構(gòu)。
醫(yī)院環(huán)境物體表面清潔的監(jiān)測(cè)方法——熒光標(biāo)記法
HAI(healthcare-associatedinfections,醫(yī)院感染/醫(yī)療相關(guān)感染)發(fā)生來(lái)自于宿主、病原體和環(huán)境之間復(fù)雜的作用。環(huán)境感染控制是醫(yī)院感染綜合預(yù)防控制措施之一。醫(yī)院的環(huán)境表面已經(jīng)成為各種病原體的“儲(chǔ)藏庫(kù)”。一些病原體可以在物體表面存活數(shù)月之久。
2003年美國(guó) j i bing 控制預(yù)防中心醫(yī)療機(jī)構(gòu)環(huán)境表面的環(huán)境感染控制指南中推薦醫(yī)院對(duì)“高頻接觸表面”進(jìn)行清潔。
醫(yī)院環(huán)境清潔的監(jiān)測(cè)方法
美國(guó)CDC網(wǎng)站發(fā)布的Options for EvaluatingEnvironmental Cleaning(環(huán)境清潔的評(píng)價(jià)方法),介紹了CDC環(huán)境檢查表和評(píng)價(jià)醫(yī)院環(huán)境物體表面的客觀方法。
CDC環(huán)境檢查表
優(yōu)先評(píng)估每個(gè)病房的以下位置:

如果房間有下列設(shè)備時(shí),應(yīng)對(duì)其進(jìn)行評(píng)估:

考核人員對(duì)清潔后的物體表面按照檢查表內(nèi)容進(jìn)行評(píng)估,客觀評(píng)價(jià)清潔質(zhì)量,并用于教育干預(yù)的定量監(jiān)測(cè)。
評(píng)價(jià)醫(yī)院環(huán)境物體表面的客觀方法
在2016年《醫(yī)療機(jī)構(gòu)環(huán)境表面清潔管理規(guī)范》的醫(yī)療機(jī)構(gòu)環(huán)境清潔衛(wèi)生審核方法化學(xué)法中推薦熒光標(biāo)記法
將熒光標(biāo)記在鄰近患者診療區(qū)域內(nèi)高頻接觸的環(huán)境表面。在環(huán)境清潔服務(wù)人員實(shí)施清潔工作前預(yù)先標(biāo)記,清潔后借助紫外線燈檢查熒光標(biāo)記是否被有效清潔,計(jì)算有效的熒光標(biāo)記清潔率,考核環(huán)境清潔工作質(zhì)量。

LUYOR-3130C UV TORCH KIT
Innovative, effective tool to environmental cleaning,for training and education
Effectively Evaluate Cleaning techniques Includes five UV pens, a torch, and instructions。
The LUYOR-3130C UV Torch Kit includes a powerful led ultra violet torch, two non-permanent, ultra violet,water soluble marker pens. It is designed as a training tool to enable healthcare professionals to learn about high touch surfaces and transference in a practical setting.
High touch surfaces are those that have frequent contact with hands and are found to harbour the most microorganisms. It is essential that all surfaces and equipment are cleaned properly, but as hands are the most common mechanism of transferring microorganisms from one surface to another, particular importance should be given to these high touch surfaces.
HOW TO USE
Read the instructions carefully. Unscrew the end of the torch, insert 1 Li-on recharge batteries into the removable chamber, and rescrew cap.
Mark the areas around the room, listed on the sheet, with the UV pen with a 5-10mm circle.
Invite someone in to the room and ask them to clean it.
When they have finished, use the UV torch to identify the high touch point which have been missed when cleaning.
SURFACES:
Bathroom areas
Bed frames
Bedside cabinets
Chairs
Countertops
Desks
Door handles
Examination
couches
Ledges
Mattresses
Table tops
Taps
Trolleys
EQUIPMENT:
Bins
Commodes
Dressing trolleys
Drip & equipment
stands
ECG machines
Keyboards &
accessories
Light switches
Sinks
Telephones