国产精品久久久久久亚洲,国产成人无码午夜视频在线观看 ,国产福利一区二区三区在线观看,国产av第一次处破,厨房玩弄丝袜人妻系列国产电影

首頁(yè) >>> 產(chǎn)品目錄 >>> RSD RS-250頭部CT模體,RS-250頭部彷真CT模體
儀表展覽網(wǎng) >>> 展館展區(qū) >>> RSD RS-250頭部CT模體,RS-250頭部彷真CT模體
> RSD RS-250頭部CT模體,RS-250頭部彷真CT模體

產(chǎn)品資料

RSD RS-250頭部CT模體,RS-250頭部彷真CT模體

RSD RS-250頭部CT模體,RS-250頭部彷真CT模體
  • 如果您對(duì)該產(chǎn)品感興趣的話,可以
  • 產(chǎn)品名稱:RSD RS-250頭部CT模體,RS-250頭部彷真CT模體
  • 產(chǎn)品型號(hào):RS-250
  • 產(chǎn)品展商:美國(guó)RSD
  • 產(chǎn)品文檔:無相關(guān)文檔
簡(jiǎn)單介紹
RSD RS-250 頭部CT模體,RS-250頭部彷真CT模體特點(diǎn): 擬人化 被鑄造的Acround頭骨 檢查重要的物理參數(shù) 提供真實(shí)的系統(tǒng)檢查 理想的培訓(xùn) 聚碳酸酯底座的尺寸適用于與縱軸平行或垂直的掃描
產(chǎn)品描述
RSD RS-250 頭部CT模體,RS-250頭部彷真CT模體特點(diǎn):
擬人化
被鑄造的Acround頭骨
檢查重要的物理參數(shù)
提供真實(shí)的系統(tǒng)檢查
理想的培訓(xùn)
聚碳酸酯底座的尺寸適用于與縱軸平行或垂直的掃描

RSD RS-250 頭部CT模體,RS-250頭部彷真CT模體

A部分: 0.4毫米厚的鋁板設(shè)置45°角,測(cè)量光束寬度和切片厚度。  
 RS-250 A部分

RSD RS-250 頭部CT模體,RS-250頭部彷真CT模體

B部分:劑量測(cè)定部分提供患者暴露控制,并在實(shí)際患者掃描前檢查異常內(nèi)部劑量。定制容納TLD與棒或芯片是可用的。  
 RS-250 B部分
RSD RS-250 頭部CT模體,RS-250頭部彷真CT模體

C部分:分級(jí)大小和放射性的圓柱形腫瘤建立高對(duì)比度和低對(duì)比度分辨率,并顯示部分光束平均效應(yīng)。    
RS-250 C部分
RSD RS-250 頭部CT模體,RS-250頭部彷真CT模體

D部分:擬人部分在空氣對(duì)比的內(nèi)耳和骨折的巖骨中提供實(shí)際的聽覺小骨。后顱窩小腫瘤被放置在大多數(shù)掃描儀難以成像的區(qū)域。  

 RS-250 D部分
RSD RS-250 頭部CT模體,RS-250頭部彷真CT模體

E部分:人體模型縱軸上1/4英寸直徑的鋁棒,檢查一般對(duì)準(zhǔn)情況,“干水”給出了一個(gè)現(xiàn)實(shí)的“噪音檢查”。

RSD RS-250 頭部CT模體,RS-250頭部彷真CT模體

CT Head with 5 slices to test all parameters of computerized tomography
Anthropomorphic
Molded Around Skull
Checks Important Physical Parameters
Provides Realistic System Check
Ideal For Training
Polycarbonate Base Dimensioned For Scans Parallel or Perpendicular to Longitudinal Axis
SECTION A: Aluminum plates, 0.4mm thick, set at a 45° angle, measure beam width and slice thickness.

SECTION B: The dosimetry section provides patient-exposure controls, and checks on abnormal internal doses before actual patient scans. Customization to accommodate TLD with rods or chips is available.

SECTION C: Cylindrical tumors of graded sizes and radiodensities establish high and low-contrast resolution and demonstrate partial beam-averaging effects.

SECTION D: The anthropomorphic section provides actual auditory ossicles in an air-contrast inner ear and a fractured petrous bone. Small tumors in the posterior fossa are placed in an area which most scanners image with difficulty.

SECTION E: 1/4 Inch diameter aluminum rod on the phantom's longitudinal axis, checks general alignment, and "DryWater" gives a realistic "noise check."
SAG:RS-250,RSD RS-250,RS-250頭部CT模體,頭部CT模體,RS-250 CT模體
產(chǎn)品留言
標(biāo)題
聯(lián)系人
聯(lián)系電話
內(nèi)容
驗(yàn)證碼
點(diǎn)擊換一張
注:1.可以使用快捷鍵Alt+S或Ctrl+Enter發(fā)送信息!
2.如有必要,請(qǐng)您留下您的詳細(xì)聯(lián)系方式!
  • 溫馨提示:為規(guī)避購(gòu)買風(fēng)險(xiǎn),建議您在購(gòu)買前務(wù)必確認(rèn)供應(yīng)商資質(zhì)與產(chǎn)品質(zhì)量。
  • 免責(zé)申明:以上內(nèi)容為注冊(cè)會(huì)員自行發(fā)布,若信息的真實(shí)性、合法性存在爭(zhēng)議,平臺(tái)將會(huì)監(jiān)督協(xié)助處理,歡迎舉報(bào)
產(chǎn)品留言
標(biāo)題
內(nèi)容
聯(lián)系人
聯(lián)系電話
電子郵件
公司名稱
聯(lián)系地址
驗(yàn)證碼
點(diǎn)擊換一張
注:1.可以使用快捷鍵Alt+S或Ctrl+Enter發(fā)送信息!
2.如有必要,請(qǐng)您留下您的詳細(xì)聯(lián)系方式!